Set Appliance State:
Mains Power Off
Turn Hot Water Tap On
Gain access to PCB (use Insulation Mat as required)
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the voltage at pin 7 of X7 on the PCB to a suitable earth point.
Voltage should be approximately 1.7V DC.
Voltage should be approximately 1.7V DC.

Isolate as per TOPs P4
and refit as necessary