Set Appliance State:
Gas Off
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Attach U-gauge to gas inlet pressure test point
Gas On
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
If required, reset boiler.
Allow burner to ignite and establish.
Inlet pressure should remain above N.G. 20 mb, L.P.G. 37mb throughout the boiler operation.
Note.
When the test is complete the pressure test point should be tightened and checked for gas soundness.
Allow burner to ignite and establish.
Inlet pressure should remain above N.G. 20 mb, L.P.G. 37mb throughout the boiler operation.
Note.
When the test is complete the pressure test point should be tightened and checked for gas soundness.