Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Unclip and remove diverter valve from appliance and place it so spindle can be observed
(diverter valve can be removed from appliance through gap between left hand manifold and the fan)
(diverter valve can be removed from appliance through gap between left hand manifold and the fan)
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Observer diverter spindle during 3 minute self-check.
It should periodically shift between fully extended and fully retracted positions.
During the self-check can the diverter valve be seen to go from fully extended to fully retracted and back to fully extended?
It should periodically shift between fully extended and fully retracted positions.
During the self-check can the diverter valve be seen to go from fully extended to fully retracted and back to fully extended?
Isolate as per TOPs P4
and refit as necessary