Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove spark generator from appliance
Measurement:
Test 1:
Measure the resistance between spades marked 1 and 2 at the spark generator.
Resistance should be greater than 1M Ohm.
Test 2:
Measure the resistance between spades marked 1 and 3 at the spark generator.
Resistance should be greater than 1M Ohm.
Test 2:
Measure the resistance between each of the three spades to earth (any part of the metal casing).
Resistance should be greater than 1M Ohm on all 3 measurements.
Measure the resistance between spades marked 1 and 2 at the spark generator.
Resistance should be greater than 1M Ohm.
Test 2:
Measure the resistance between spades marked 1 and 3 at the spark generator.
Resistance should be greater than 1M Ohm.
Test 2:
Measure the resistance between each of the three spades to earth (any part of the metal casing).
Resistance should be greater than 1M Ohm on all 3 measurements.

Isolate as per TOPs P4
and refit as necessary