Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector CN6 from the PCB
Measurement:
Test 1:
Measure the resistance between pin 39 (blue)
and pin 40 (brown) on connector CN6.
Expected resistance approximately 0.8 Kohms.
Test 2 Resistance to Earth:
Measure the resistance between pin 40 (brown)
on connector CN6 and a suitable Earth point.
Expected resistance greater than 1 Mohm.
Measure the resistance between pin 39 (blue)
and pin 40 (brown) on connector CN6.
Expected resistance approximately 0.8 Kohms.
Test 2 Resistance to Earth:
Measure the resistance between pin 40 (brown)
on connector CN6 and a suitable Earth point.
Expected resistance greater than 1 Mohm.

Isolate as per TOPs P4
and refit as necessary