Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector CN4 from the PCB
Ensure that the cold mains supply is ON
(Turn the lever 90° anti clockwise until it is facing down)
Ensure that the cold mains supply is ON
(Turn the lever 90° anti clockwise until it is facing down)
Measurement:
Measure the resistance between pin 16 (green)
and pin 17 (green) on connector CN4.
Expected resistance open circuit.
Run a hot tap at 2 litres/min and repeat above test.
Expected resistance short circuit.
and pin 17 (green) on connector CN4.
Expected resistance open circuit.
Run a hot tap at 2 litres/min and repeat above test.
Expected resistance short circuit.

Isolate as per TOPs P4
and refit as necessary