Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector CN6 from the PCB
Disconnect the connection from the pump assembly
Disconnect the connection from the pump assembly
Measurement:
Test 1:
Measure the resistance between pin 4 on the
pump connector and pin 44 (Black) on connector CN6.
Test 2:
Measure the resistance between pin 1 on the
pump connector and pin 43 (Black) on connector CN6.
Expect continuity/zero resistance on each test.
Also visually inspect the condition of the harness.
Measure the resistance between pin 4 on the
pump connector and pin 44 (Black) on connector CN6.
Test 2:
Measure the resistance between pin 1 on the
pump connector and pin 43 (Black) on connector CN6.
Expect continuity/zero resistance on each test.
Also visually inspect the condition of the harness.

Isolate as per TOPs P4
and refit as necessary