Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector CN6 from the PCB
Measurement:
Measure the resistance between pin 39 (blue)
and pin 40 (brown) on connector CN6.
Expected resistance approximately 0.8 Kohms.
and pin 40 (brown) on connector CN6.
Expected resistance approximately 0.8 Kohms.

Isolate as per TOPs P4
and refit as necessary