Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector CN4 from the PCB
Disconnect the plug from the thermal fuse
Disconnect the plug from the thermal fuse
Measurement:
Test 1:
Measure the resistance between pin 1 (black) on the
thermal fuse connector and pin 24 (black) on connector CN4.
Test 2:
Measure the resistance between pin 2 (black) on the
thermal fuse connector and pin 25 (black) on connector CN4.
Expect continuity/zero resistance on each of the above tests.
Also visually inspect the condition of the harness.
Measure the resistance between pin 1 (black) on the
thermal fuse connector and pin 24 (black) on connector CN4.
Test 2:
Measure the resistance between pin 2 (black) on the
thermal fuse connector and pin 25 (black) on connector CN4.
Expect continuity/zero resistance on each of the above tests.
Also visually inspect the condition of the harness.

Isolate as per TOPs P4
and refit as necessary