Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to AC Volts Set meter to measure AC Volts
Turn Hot Water Tap On
Use Insulation Mat as required
Gain access to PCB
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Allow the fan to run and the ignition sequence to commence.
Measure the AC voltage between pin 39 (blue)
and pin 40 (brown) on connector CN6 during the ignition phase.
Mains voltage should be present for 5 seconds, this will then be present again after approximately 7 seconds. This will be repeated 3 times before lockout occurs, reset as required until test is complete.
Note:
Place the probes in the small holes on the PCB.