Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the burner door assembly complete with burner
Observation:
1. Inspect the burner for restrictions and any signs of damage.
2. Measure the gap between the ionisation electrode and burner.
The gap should measure approximately 18.7mm +/- 1mm.
Note.
Refer to adapt regarding any gasket replacement requirements.
2. Measure the gap between the ionisation electrode and burner.
The gap should measure approximately 18.7mm +/- 1mm.
Note.
Refer to adapt regarding any gasket replacement requirements.