Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove ignition electrode
Disconnect lead at spark generator
Disconnect lead at spark generator
Measurement:
Thoroughly check the spark electrode for wear, contamination, cracks and damage, confirm electrode gap is 4mm +0.5mm
Measure the resistance across the electrode and lead.
Expected resistance approximately 1 kOhm.
Note.
Refer to adapt regarding any gasket
replacement requirements.
Measure the resistance across the electrode and lead.
Expected resistance approximately 1 kOhm.
Note.
Refer to adapt regarding any gasket
replacement requirements.

Isolate as per TOPs P4
and refit as necessary