Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connectors CN13 & CN15 from the PCB
Disconnect electrical connector to pump assembly
Disconnect electrical connector to pump assembly
Measurement:
Measure the continuity of the pump harness, connections are (see table).
Expect continuity/zero resistance on each test.
Expect continuity/zero resistance on each test.

Isolate as per TOPs P4
and refit as necessary