Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the burner door assembly complete with burner
Observation:
1. Inspect the burner for restrictions and any signs of damage.
2. Measure the gap between the tip of the ignition electrode and the burner.
The gap should measure approximately 18mm.
3. Measure the gap between the ionisation electrode and the burner.
The gap should measure approximately 18.7mm +/- 1mm.
Note.
Refer to adapt regarding any gasket replacement requirements.
2. Measure the gap between the tip of the ignition electrode and the burner.
The gap should measure approximately 18mm.
3. Measure the gap between the ionisation electrode and the burner.
The gap should measure approximately 18.7mm +/- 1mm.
Note.
Refer to adapt regarding any gasket replacement requirements.