Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Gain access to PCB (use Insulation Mat as required)
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Test 1.
Measure for DC voltage across pin 40 of connector CN2 & and pin 4 of connector CN4.
Make a note of the voltage reading.
Test 2.
Add some pressure to the system, then repeat test one.
Has the voltage increased from the reading obtained in test 1?