Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Gain access to PCB (use Insulation Mat as required)
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Cancel purge cycle.
Allow fan to run and ignition sequence to commence.
During the sparking stage of the ignition cycle measure the DC voltage between pin 8 (grey) and pin 17 (grey) on connector X4.
Expect approximately 22 Vdc or greater.
Is the voltage as expected?
Note:
Appliance may lockout during this test reset as necessary to confirm results.