Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the connector from the gas valve
Measurement:
Test 1:
Measure the resistance between the two pins on the gas valve.
Expect approximately 116 ohms.
Test 2:
Measure the resistance between one pin (either) on the
gas valve individually to a suitable earth point.
Expected resistance greater than 1 MOhm.
Measure the resistance between the two pins on the gas valve.
Expect approximately 116 ohms.
Test 2:
Measure the resistance between one pin (either) on the
gas valve individually to a suitable earth point.
Expected resistance greater than 1 MOhm.

Isolate as per TOPs P4
and refit as necessary