Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
Remove the connector from the fan assembly and make safe
Remove the connector from the fan assembly and make safe
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
This test can be carried out during the purge cycle.
Measure the DC voltages between pin 4 (brown), pin 5 (orange) and pin 16 (pink) on connector X3 to a suitable earth point.
The voltages should conform approximately to the table below:
Measure the DC voltages between pin 4 (brown), pin 5 (orange) and pin 16 (pink) on connector X3 to a suitable earth point.
The voltages should conform approximately to the table below:
| Connector X3 | DC voltage | Pin 4 (brown) | 16.6 |
| Pin 5 (orange) | 20.4 |
| Pin 16 (pink) | 22.0 |

Isolate as per TOPs P4
and refit as necessary