Set Appliance State:
Ensure NO demands
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the DC voltage between pin 2 (Red) on
connector X3 to a suitable earth point.
Expect approximately 12.7 vdc.
connector X3 to a suitable earth point.
Expect approximately 12.7 vdc.

Isolate as per TOPs P4