Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Turn Hot Water Tap On
Gain access to PCB (use Insulation Mat as required)
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

This test can be carried out during the purge cycle.
Run the DHW tap with a flow rate of 2 l/min.
Measure the DC voltage between pin 1 (Blue) on
connector X3 to a suitable earth point.
Expect approximately 2.7 Vdc.