Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the connector from the fan assembly
Remove connector X2 from the PCB
Remove connector X2 from the PCB
Measurement:
Test 1.
Measure the resistance between pin 4 (green) and
pin 10 (green) on connector X2.
Test 2.
Measure the resistance between pin 4 (green) and pin 10 (green) on
connector X2 individually to a suitable earth point.
Expected resistance greater than 1 MOhm for each test.
Note.
A reading of O.L is acceptable as this is greater than 1 MOhm.
Measure the resistance between pin 4 (green) and
pin 10 (green) on connector X2.
Test 2.
Measure the resistance between pin 4 (green) and pin 10 (green) on
connector X2 individually to a suitable earth point.
Expected resistance greater than 1 MOhm for each test.
Note.
A reading of O.L is acceptable as this is greater than 1 MOhm.

Isolate as per TOPs P4
and refit as necessary