Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector X1 from the PCB
Remove the plug from the pump assembly
Remove the plug from the pump assembly
Measurement:
Measure the resistance of both the blue and brown wires running from the pump plug to pins 1 and 2 at X1 on the PCB.
Expect continuity / zero resistance on each test.
Also visually inspect the condition of the wiring and connectors.
Note:
Pump plug may differ in appearance
but test remains the same.
Expect continuity / zero resistance on each test.
Also visually inspect the condition of the wiring and connectors.
Note:
Pump plug may differ in appearance
but test remains the same.

Isolate as per TOPs P4
and refit as necessary