Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Gain access to PCB (use Insulation Mat as required)
Remove connector X3 from the PCB

Measurement:

Measure the resistance between pins 19 and 20 on connector X3.
Resistance should be short circuit (zero resistance).