Set Appliance State:
Turn Hot Water Tap On
DHW set to Maximum Temperature (50°C)
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Allow burner to ignite and boiler to run on DHW.
With a flow rate at the tap of approximately 10 litres/min, is there a temperature rise of approximately 35°C and is operation satisfactory?
Note:
The appliance is factory set to have a maximum DHW temperature of 50°C, this maximum can be set to between 50 and 65°C. If the maximum DHW temp requires adjustment this will need to be changed in the PCB parameters, please refer to the "Other" section in Adapt. Once a diagnosis has been made remember to reset this as appropriate for the customer.
With a flow rate at the tap of approximately 10 litres/min, is there a temperature rise of approximately 35°C and is operation satisfactory?
Note:
The appliance is factory set to have a maximum DHW temperature of 50°C, this maximum can be set to between 50 and 65°C. If the maximum DHW temp requires adjustment this will need to be changed in the PCB parameters, please refer to the "Other" section in Adapt. Once a diagnosis has been made remember to reset this as appropriate for the customer.