Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the ignition lead from the spark generator
Measurement:
Measure the resistance between the end of the ignition lead and the earth at the incoming mains supply (X11).
Expect a resistance greater than 1Mohm.
Is the resistance as expected?
Note:
The ignition lead may differ in appearance but the test is
carried out in the same way.
Expect a resistance greater than 1Mohm.
Is the resistance as expected?
Note:
The ignition lead may differ in appearance but the test is
carried out in the same way.

Isolate as per TOPs P4
and refit as necessary