Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the two wires from the outdoor sensor connections (terminals 3 and 4 at the boilers main terminal strip) and make safe
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
There is no need to wait for the fan purge to finish before commencing this test.
Has the fault code F39 for the outdoor sensor cleared?
Has the fault code F39 for the outdoor sensor cleared?
Isolate as per TOPs P4
and refit as necessary