Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
There is no need to wait for the fan purge to finish before commencing this test.
Measure the AC voltage between the two outer pins of connector X2 on the PCB.
Expect mains voltage.
Is the voltage measured as expected?
Measure the AC voltage between the two outer pins of connector X2 on the PCB.
Expect mains voltage.
Is the voltage measured as expected?

Isolate as per TOPs P4
and refit as necessary