Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the cover from the pump assembly
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the AC voltage between the live and neutral wires at the pump assembly.
Expect the mains voltage to the pump to cycle, it should be present for 5 seconds and then absent for 5 seconds, this cycle will be repeated for up to 2 minutes.
Does the voltage to the pump behave as described above?
Note:
It can take up to 20 seconds for the voltage to appear at the pump the first time after power is switched on.
Expect the mains voltage to the pump to cycle, it should be present for 5 seconds and then absent for 5 seconds, this cycle will be repeated for up to 2 minutes.
Does the voltage to the pump behave as described above?
Note:
It can take up to 20 seconds for the voltage to appear at the pump the first time after power is switched on.

Isolate as per TOPs P4
and refit as necessary