Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Remove connector X4 from the PCB

Measurement:

Test 1:
Measure the resistance between pin 3 and pin 4 on connector X4.
Expect approximately 3.1 kohms.
Test 2:
Measure the resistance between pin 4 and the earth at the incoming mains supply.
Expect a resistance greater than 1 Mohm.
Are the resistances measured as expected?