Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
There is no need to wait for the fan purge to finish before commencing this test.
Measure the DC voltage between pin 11 on connector X5 and the earth on the incoming mains supply.
Expect either 0 vdc or 4.5 vdc.
Measure the DC voltage between pin 11 on connector X5 and the earth on the incoming mains supply.
Expect either 0 vdc or 4.5 vdc.

Isolate as per TOPs P4
and refit as necessary