Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
DHW Demand
DHW temperature control on MAX
Attach U-gauge to burner pressure test point
To check minimum burner pressure remove one lead from Modureg and make safe
To check maximum both leads on Modureg and DHW tap on full
WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure
Mains Power On

Observation:

Check burner pressure at Max and Min.
Both must be set correctly.
11.8mbar MAX
2.5mbar MIN
Note:
When gauge is removed pressure test point should be tightened and checked for gas tightness.