Set Appliance State:
Isolate Mains Power to appliance as per TOPs P4
Remove the diverter valve actuator from the diverter valve body
Note:
The diverter valve motor can be removed without draining the appliance.
Unscrew the locating screw and push the motor assembly downwards,
the assembly will slide free from the valve.
Remove the diverter valve actuator from the diverter valve body
Note:
The diverter valve motor can be removed without draining the appliance.
Unscrew the locating screw and push the motor assembly downwards,
the assembly will slide free from the valve.
Measurement:
Measure the resistance across the DV pins.
Resistances should be approximately as follows;
Note:
Care should be taken that probe tips
do not touch each other when taking measurement as a false reading will be given.
Resistances should be approximately as follows;
| Test | Resistance (kohms) | |
| 1. | 12.7 | |
| 2. | 12.7 |
Note:
Care should be taken that probe tips
do not touch each other when taking measurement as a false reading will be given.

Isolate as per TOPs P4
and refit as necessary