Set Appliance State:

Set Multimeter to Resistance Set meter to measure resistance
Isolate Mains Power to appliance as per TOPs P4
Remove the diverter valve actuator from the diverter valve body
Note:
The diverter valve motor can be removed without draining the appliance.
Unscrew the locating screw and push the motor assembly downwards,
the assembly will slide free from the valve.

Measurement:

Measure the resistance across the DV pins.
Resistances should be approximately as follows;
Test

Across Leads

Resistance (Kohms)

1.

1 & 3

12.7

2.

4 & 6

12.7


Note:
Care should be taken that probe tips
do not touch each other when taking measurement as a false reading will be given.