Set Appliance State:
Mains Power Off
DHW Demand
DHW Selector in Maximum (+) position
CH Selector in Minimum (-) position
ON/OFF Switch in ON position
DHW Selector in Maximum (+) position
CH Selector in Minimum (-) position
ON/OFF Switch in ON position
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Observation:
Allow boiler to ignite and run
With a flow rate at the tap of approximately 9.8 litres/min is there a temperature rise of 35° C and is operation satisfactory?
With a flow rate at the tap of approximately 9.8 litres/min is there a temperature rise of 35° C and is operation satisfactory?