Set Appliance State:
Isolate Mains Power to appliance as per TOPs P4
DHW Demand
DHW Selector in Maximum (+) position
CH Selector in Minimum (-) position
ON/OFF Switch in ON position
Remove the plug from X2B IGNITER / FLAME SENSE
DHW Demand
DHW Selector in Maximum (+) position
CH Selector in Minimum (-) position
ON/OFF Switch in ON position
Remove the plug from X2B IGNITER / FLAME SENSE
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Measurement:
Using shrouded probes measure the voltage across clear and blue labelled terminals on the PCB at X2B IGNITER / FLAME SENSE on the rear of the lowered control box.
Expect 130 V AC.
Expect 130 V AC.

Isolate as per TOPs P4
and refit as necessary