Set Appliance State:

Gas Off
Isolate Mains Power to appliance as per TOPs P4
DHW Demand
DHW Selector in Maximum (+) position
CH Selector in Minimum (-) position
ON/OFF Switch in ON position
Attach U-gauge to the inlet pressure test point
Gas On
WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure
Mains Power On

Measurement:

Allow Fan to run and ignition sequence to commence.
Does the pressure gauge show an acceptable minimum
gas inlet pressure of at least 18mb throughout its operation ?
Note:
When pressure gauge is removed the pressure test point should be tightened and checked for gas tightness.