Set Appliance State:
Mains Power Off
Gas On; Pilot On
Rotary Switch in DHW position
Keep gas valve control knob depressed
Keep gas valve control knob depressed
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Measurement:
Measure the DC voltage across one terminal of the overheat thermostat and the boiler chassis.
Repeat the test using the other terminal of the overheat thermostat and the boiler chassis.
Repeat the test using the other terminal of the overheat thermostat and the boiler chassis.

Isolate as per TOPs P4
and refit as necessary