Set Appliance State:
Mains Power Off
Gas On; Pilot On
CH Demand
Rotary Switch in CH and DHW position
CH Thermostat adjusted to Maximum
Attach a U-gauge to the gas valve outlet pressure test point
Keep Boiler Case Switch depressed
CH Thermostat adjusted to Maximum
Attach a U-gauge to the gas valve outlet pressure test point
Keep Boiler Case Switch depressed
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Measurement:
Does the burner crosslight from the pilot and after a few seconds operate at its set burner pressure of between 3.2-7.6mb?
Notes:
Factory heat setting is 3.2mb, the maximum setting is 7.6mb.
When U-gauge is removed pressure nipple should be tightened & checked for gas soundness.
Notes:
Factory heat setting is 3.2mb, the maximum setting is 7.6mb.
When U-gauge is removed pressure nipple should be tightened & checked for gas soundness.
Isolate as per TOPs P4
and refit as necessary