Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the connector from the DHW flow sensor and make safe
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure for DC volts across pin 3 (yellow lead) connector X2 and a suitable earth connection.
Expected voltage approximately 4.8 Vdc.
Note.
Pins are numbered on the connectors.
Expected voltage approximately 4.8 Vdc.
Note.
Pins are numbered on the connectors.

Isolate as per TOPs P4
and refit as necessary