Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to pump terminals
Remove wiring from pump terminals
Remove wiring from pump terminals
Measurement:
Test 1:
Measure the resistance between the live and neutral connections on the pump.
Expect a resistance of approximately 220 ohms.
Test 2:
Measure the resistance between the live and earth connections on the pump.
Expect a resistance of 1Mohm or greater.
(O.L. is acceptable because it is greater than 1 MOhm)
Are the resistances measured as expected?
Measure the resistance between the live and neutral connections on the pump.
Expect a resistance of approximately 220 ohms.
Test 2:
Measure the resistance between the live and earth connections on the pump.
Expect a resistance of 1Mohm or greater.
(O.L. is acceptable because it is greater than 1 MOhm)
Are the resistances measured as expected?

Isolate as per TOPs P4
and refit as necessary