Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
Remove connector X20 from the PCB
Remove connector X20 from the PCB
Measurement:
Test 1:
Measure for resistance across pins 9 & 18 (green leads) of connector X20.
Expected resistance approximately 54.0 Ohms.
Test 2:
Measure the resistance between pin 9 on connector X20 and a suitable earth.
Expect a resistance of 1MOhm or greater.
Are the resistances measured as expected?
Note.
Ensure a good connection is made as misdiagnosis will occur.
Measure for resistance across pins 9 & 18 (green leads) of connector X20.
Expected resistance approximately 54.0 Ohms.
Test 2:
Measure the resistance between pin 9 on connector X20 and a suitable earth.
Expect a resistance of 1MOhm or greater.
Are the resistances measured as expected?
Note.
Ensure a good connection is made as misdiagnosis will occur.

Isolate as per TOPs P4
and refit as necessary