Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector X2 from the PCB
Remove connector to system pressure sensor
Remove connector to system pressure sensor
Measurement:
Measure for resistance across each wire of the system pressure sensor harness, pins 11,13,14 of X2 to the corresponding wire on the sensor connector. (e.g. orange lead (pin 11) X2 connector to orange lead of system pressure sensor connector).
Expect continuity / zero resistance on each wire.
Notes:
1. The colours of the wires in the harness may differ but the test points remain the same.
2. To make it easier to carry out the test it is acceptable to leave connector X2 attached to the PCB if you wish.
Expect continuity / zero resistance on each wire.
Notes:
1. The colours of the wires in the harness may differ but the test points remain the same.
2. To make it easier to carry out the test it is acceptable to leave connector X2 attached to the PCB if you wish.

Isolate as per TOPs P4
and refit as necessary