Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the wires from terminals 3 and 5 on the timer
Timer set to ON
Timer set to ON
Measurement:
Measure the resistance between terminals 3 and 5 on the timer.
Expect open circuit / O.L.
Is the resistance measured as expected?
Expect open circuit / O.L.
Is the resistance measured as expected?

Isolate as per TOPs P4
and refit as necessary