Set Appliance State:
Mains Power Off
Disconnect X1 from the PCB
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Test 1:
Measure for DC voltage between pin 66 on X1 to a suitable earth point.
Voltage should be approximately 4.6V DC.
Test 2:
Measure for DC voltage between pin 74 on X1 to a suitable earth point.
Voltage should be approximately 36V DC.
Test 3:
Measure for DC voltage between pin 75 on X1 to a suitable earth point.
Voltage should be approximately 4.6V DC.
Note.
Ensure a good connection is made and probe is only making contact with one pin else misdiagnosis will occur.
Measure for DC voltage between pin 66 on X1 to a suitable earth point.
Voltage should be approximately 4.6V DC.
Test 2:
Measure for DC voltage between pin 74 on X1 to a suitable earth point.
Voltage should be approximately 36V DC.
Test 3:
Measure for DC voltage between pin 75 on X1 to a suitable earth point.
Voltage should be approximately 4.6V DC.
Note.
Ensure a good connection is made and probe is only making contact with one pin else misdiagnosis will occur.

Isolate as per TOPs P4
and refit as necessary