Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect X1 (ribbon cable) from main PCB
(this affects resistances and must be done to prevent misdiagnosis)
Gain access to back of display PCB
(this affects resistances and must be done to prevent misdiagnosis)
Gain access to back of display PCB
Measurement:
Test 1:
Measure the resistance between connections 1 and 3 on the display PCB.
Resistance should be approximately 3.5kΩ.
Test 2:
Measure the resistance between connections 2 and 3 on the display PCB.
Resistance should be approximately 2kΩ.
Measure the resistance between connections 1 and 3 on the display PCB.
Resistance should be approximately 3.5kΩ.
Test 2:
Measure the resistance between connections 2 and 3 on the display PCB.
Resistance should be approximately 2kΩ.

Isolate as per TOPs P4
and refit as necessary