Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to AC Volts Set meter to measure AC Volts
Remove connector X2 (detection electrode lead) from the PCB
Ensure NO demands are present
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Reset appliance if required (rotate selector switch to OFF position
for 4 seconds, then rotate back to DHW/CH position).
Measure for A/C voltage across X2 terminal and a suitable earth connection.
Expected voltage measured approximately 170 Vac.