Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove left hand side panel
Disconnect fan leads
Disconnect fan leads
Measurement:
Test 1. Measure for resistance across fan terminals.
Expected resistance approximately 46 Ohms.
Test 2. Measure for resistance across one terminal of the fan and a suitable earth connection.
Expected resistance greater than 1 Mohm.
Expected resistance approximately 46 Ohms.
Test 2. Measure for resistance across one terminal of the fan and a suitable earth connection.
Expected resistance greater than 1 Mohm.

Isolate as per TOPs P4
and refit as necessary