Set Appliance State:
Mains Power Off
Ensure NO demands are present
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
When power is switched on the boiler will run a self check.
Allow 30 seconds for self test to complete before proceeding.
If self check has completed successfully the ON led will be illuminated.
If a FAULT CODE is flashing, choose fault codes below
(shown as any led flashing).
Allow 30 seconds for self test to complete before proceeding.
If self check has completed successfully the ON led will be illuminated.
If a FAULT CODE is flashing, choose fault codes below
(shown as any led flashing).