Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the electrical connector from the gas valve
Measurement:
Test 1.
Measure the resistance between the 2 pins on the gas valve.
Expected resistance approx. 9.3 KOhms.
Test 2.
Measure the resistance between pin 2 on the
gas valve to a suitable earth point.
Expected resistance greater than 1 MOhm.
Note.
A reading of O.L on test 2 is acceptable as this is greater than 1 MOhm.
Measure the resistance between the 2 pins on the gas valve.
Expected resistance approx. 9.3 KOhms.
Test 2.
Measure the resistance between pin 2 on the
gas valve to a suitable earth point.
Expected resistance greater than 1 MOhm.
Note.
A reading of O.L on test 2 is acceptable as this is greater than 1 MOhm.

Isolate as per TOPs P4
and refit as necessary