Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Unplug the electrical connector from the pump assembly
Measurement:
Test 1.
Measure the resistance between pin 1 (black) on the
pump electrical connector to the black wire on
connector CN25.
Test 2.
Measure the resistance between pin 2 (brown) on the
pump electrical connector to the brown wire on
connector CN25.
Expect continuity / zero resistance on each test.
Also visually inspect the condition of the harness.
Measure the resistance between pin 1 (black) on the
pump electrical connector to the black wire on
connector CN25.
Test 2.
Measure the resistance between pin 2 (brown) on the
pump electrical connector to the brown wire on
connector CN25.
Expect continuity / zero resistance on each test.
Also visually inspect the condition of the harness.

Isolate as per TOPs P4
and refit as necessary